;driver sceletone
 
format MS COFF
 
include 'proc32.inc'
 
 
OS_BASE equ 0;
new_app_base equ 0x60400000
PROC_BASE equ OS_BASE+0x0080000
 
struc IOCTL
{ .handle dd ?
.io_code dd ?
.input dd ?
.inp_size dd ?
.output dd ?
.out_size dd ?
}
 
virtual at 0
IOCTL IOCTL
end virtual
 
public START
public service_proc
 
extrn AttachIntHandler
extrn SysMsgBoardStr
extrn PciApi
extrn PciRead32
extrn PciRead8
extrn PciWrite8
extrn AllocKernelSpace
extrn KernelAlloc
extrn MapPage
extrn GetPgAddr
extrn RegService
extrn ServiceHandler
extrn SetHwCursor
extrn LFBAddress
extrn LoadFile
extrn FpuSave
extrn FpuRestore
 
DEBUG equ 1
 
DRV_ENTRY equ 1
DRV_EXIT equ -1
STRIDE equ 4 ;size of row in devices table
 
section '.flat' code readable align 16
 
proc START stdcall, state:dword
 
mov eax, [state]
cmp eax, 1
je .entry
jmp .exit
.entry:
if DEBUG
mov esi, msgInit
call SysMsgBoardStr
end if
 
stdcall RegService, my_service, service_proc
ret
.fail:
.exit:
xor eax, eax
ret
endp
 
handle equ IOCTL.handle
io_code equ IOCTL.io_code
input equ IOCTL.input
inp_size equ IOCTL.inp_size
output equ IOCTL.output
out_size equ IOCTL.out_size
 
align 4
proc service_proc stdcall, ioctl:dword
 
; mov edi, [ioctl]
; mov eax, [edi+io_code]
 
xor eax, eax
ret
endp
 
restore handle
restore io_code
restore input
restore inp_size
restore output
restore out_size
 
align 4
proc detect
locals
last_bus dd ?
endl
 
xor eax, eax
mov [bus], eax
inc eax
call PciApi
cmp eax, -1
je .err
 
mov [last_bus], eax
 
.next_bus:
and [devfn], 0
.next_dev:
stdcall PciRead32, [bus], [devfn], dword 0
test eax, eax
jz .next
cmp eax, -1
je .next
 
mov edi, devices
@@:
mov ebx, [edi]
test ebx, ebx
jz .next
 
cmp eax, ebx
je .found
add edi, STRIDE
jmp @B
 
.next: inc [devfn]
cmp [devfn], 256
jb .next_dev
mov eax, [bus]
inc eax
mov [bus], eax
cmp eax, [last_bus]
jna .next_bus
xor eax, eax
ret
.found:
xor eax, eax
inc eax
ret
.err:
xor eax, eax
ret
endp
 
 
;DEVICE_ID equ ; pci device id
;VENDOR_ID equ ; device vendor id
 
 
;all initialized data place here
 
align 4
devices dd (DEVICE_ID shl 16)+VENDOR_ID
dd 0 ;terminator
 
my_service db 'MY_SERVICE',0 ;max 16 chars include zero
 
msgInit db 'detect hardware...',13,10,0
msgPCI db 'PCI accsess not supported',13,10,0
msgFail db 'device not found',13,10,0
 
section '.data' data readable writable align 16
 
;all uninitialized data place here