1450,20 → 1450,6 |
* To get system time use function 3. |
|
====================================================================== |
===================== Function 26, subfunction 10 ==================== |
========== Get the value of the high precision time counter. ========= |
====================================================================== |
Parameters: |
* eax = 26 - function number |
* ebx = 10 - subfunction number |
Returned value: |
* eax = number of nanoseconds since system boot time (lower DWORD) |
* edx = number of nanoseconds since system boot time (high DWORD) |
Remarks: |
* The counter is based on HPET, if HPET is not available, resolution |
will be reduced to 10 000 000 nanoseconds. |
|
====================================================================== |
===================== Function 26, subfunction 11 ==================== |
========== Find out whether low-level HD access is enabled. ========== |
====================================================================== |